ROCK 120A-H

  • Industrial-grade professional procedures, safe and reliable
  • Highly reliable start algorithm, no fear of headwind starting
  • The throttle is anti-phase loss and fast throttle response to reduce the risk of crashes
  • Highly intelligent, adaptive working parameters
  • Secure matching
  • Specification: 120A 12~26S

Features

  • The direction of rotation can be set by software
  • High-quality components, reliable performance, low internal resistance, MOS, instantaneous current resistance
  • The serial port outputs real-time data such as power supply voltage, motor speed, current, ESC temperature and debugging data.
  • Shielding signal lines reduces interference
  • Optoelectronic isolation signal input and output interfaces isolate interference
  • Lightweight design, simple and easy to use, stable and reliable, strong anti-interference ability, good speed regulation performance

protective function

  • Low voltage protection: off by default (can be customized on). 
  • High voltage protection: prohibit the motor from starting when the power supply voltage exceeds the allowable value.
  • Startup protection: If the startup is unsuccessful, the startup current will be limited, and the startup will be restarted automatically.
  • Stall protection: If a stall occurs during normal operation (usually caused by external force), try to restart (note that the stall may damage the ESC when the throtor is high).
  • Over-temperature protection: When the temperature exceeds 115°C, the maximum output power will be reduced slowly, up to 40% of the full throttle power, and the original power will be restored after the temperature is reduced. 
  • Over-current protection: limit the peak current and do not exceed the limit value. 
  • Overload Protection: When an overload is identified on the motor, the maximum throttle is limited to protect the powertrain. 
  • Loss of control protection: 200ms after the loss of signal gradually reduce the output power, in 1~2 seconds for rapid throttle reduction to less than 50%, and then slowly reduce the throttle to stop.

Basic parameter

  • Model:ROCK 120A-H
  • Voltage:12~26S
  • Size:111*64.6*32.5mm
  • Weight:370g (with wire)
  • Continuous operating current:70A (specific heat dissipation)
  • Instantaneous operating current (1 sec.):150A
  • Maximum operating current (3 seconds):120A
  • Standby power consumption:≤10mA@100V
  • Throttle travel range:1000~2000us
  • Throttle response time:400ms
  • Waterproof rating:IP54 (IP67 available upon request)
  • Power Cord:Silicone Wire-Red/Black-8AWG-150mm
  • Three-phase cable:Silicone Wire-Black-8AWG-100mm
  • Signal cable: UL1533-24AWG-Gray-530mm
  • Throttle Refresh Rate:50~500Hz (100~400Hz recommended)
  • Data feedback line:PVC cable - 30 cores - black, red and white - 70mm
  • BEC:not
  • Input signal level:3.3~5V
  • Temperature protection point:115℃
  • Means of communication:PWM
  • Operating ambient temperature:-20~+65℃

Drawings

ROCK 280A-M/CAN 工程图
Test conditions: ambient temperature 25℃, power supply voltage 100V, data for reference only
load testTesting environmentTesting timeresult
70ACooling by air circulation6 minutesNormal, MOS temperature 83°C
80AWindward heat dissipation6 minutes and 30 secondsNormal, the overheating protection gradually reduces power.
Scroll to Top